Artesyn NFS80-7606 Power Supply - Switch Mode Power Supply Simple Type: Power Supply

The NFS80 series is a 80W universal input AC/DC power supply on a 7 x 4.25 inch card. The NFS80 series has two quad output models with a very high peak capability on the auxiliary outputs for drive and motor applications. The NFS80 provides 80W of output power with free air convection cooling which can be boosted to 110W with 20CFM of forced air. Standard features include overvoltage and short circuit protection. The series, with full international safety approval and the CE mark, meets conducted emissions EN55022 level B.

Download the datasheet (PDF)

For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.

Features

  • None Available

Specifications

    General
  • Altitude: Operating:10,000 feet max.; Non-operating:30,000 feet max.
  • Approvals and standards: VDE0805, EN60950, IEC950, IEC1010, UL1950, CSA C22.2 No. 950
  • Efficiency: 70% typical
  • EMC CHARACTERISTICS: Conducted emissions EN55022, FCC part 15 Level B; Radiated emissions EN55022, FCC part 15 Level B; ESD air EN61000-4-2, level 3 Perf. criteria 1; ESD contact EN61000-4-2, level 4 Perf. criteria 1; Surge EN61000-4-5, level 3 Perf. criteria 1; Fast transients EN61000-4-4, level 3 Perf. criteria 1; Radiated immunity EN61000-4-3, level 3 Perf. criteria 1; Conducted immunity EN61000-4-6, level 3 Perf. criteria 1
  • Hold-up time: 110VAC @ 80W 35ms; 110VAC @ 110W 17ms; 230VAC @ 80W 140ms; 230VAC @ 110W 100ms
  • Input frequency range: 47Hz to 440Hz
  • Input surge current: 115VAC, cold start 19A; 230VAC, cold start 38A
  • Input voltage range: Universal input:90 to 264VAC; 120 to 370VDC
  • Isolation voltage: Input/output:3000VAC; Input/chassis:1500VAC
  • Line regulation (LL to HL, FL): Main output:±0.1% max.; Auxiliary outputs:±0.1% max.
  • Minimum output current (See derating curve): Main output:1.0A; Auxiliary output:0A
  • MTBF: MIL-HDBK-217E @ 25°C:125,000 hours
  • Output power limit: Primary power limit-160W Pin max.; 110W Pout min.
  • Overshoot/undershoot: At turn-on, 0%
  • Overvoltage protection: +5V output:140% Vout max.
  • Relative humidity: 5% to 95% RH
  • Safety ground leakage current: 110VAC, 60Hz 0.2mA; 230VAC, 50Hz 0.4mA
  • Short circuit protection: Yes with auto recovery
  • Switching frequency: 20kHz to 70kHz
  • Temperature coefficient: All outputs:±0.02%/°C
  • Thermal performance: Operating, see curve:0°C to +70°C; Non-operating:–40°C to +85°C; 50°C to +70°C:Derate; natural convection:2W/°C; 50°C to +70°C:Derate; 20CFM forced air cooling:2.75W/°C
  • Transient response: +5V (10A to 12A):150mV peak, 1ms recovery
  • Vibration: 5Hz to 500Hz:2.4G rms approx.
  • Voltage adjustability: +5V output on multi’s ±3%, Vout on singles
  • Weight: 600g (21.18oz)

 